Filters for

Results GK

Model GKG2 40-4G-0025F-X-60
Family GK
Speed Fixed speed
Max Flow Rate 10,80 m³/h
H max 28,50 m
Pump casing Cast iron GJL 250 EN 1561
Min Flow Rate 1,10 m³/h
Min head 24,30 m
kW 2,50 kW
Power consumption ---
Efficiency ---
Model GKG2 40-4M-0048H-X-60
Family GK
Speed Fixed speed
Max Flow Rate 10,80 m³/h
H max 39,10 m
Pump casing Cast iron GJL 250 EN 1561
Min Flow Rate 0,70 m³/h
Min head 28,20 m
kW 4,80 kW
Power consumption ---
Efficiency ---
Model GKG2 40-4I-0048H-X-60
Family GK
Speed Fixed speed
Max Flow Rate 10,80 m³/h
H max 44,10 m
Pump casing Cast iron GJL 250 EN 1561
Min Flow Rate 0,70 m³/h
Min head 34,50 m
kW 4,80 kW
Power consumption ---
Efficiency ---
Model GKG2 40-4I-0065H-X-60
Family GK
Speed Fixed speed
Max Flow Rate 14,40 m³/h
H max 47,40 m
Pump casing Cast iron GJL 250 EN 1561
Min Flow Rate 0,70 m³/h
Min head 35,50 m
kW 6,50 kW
Power consumption ---
Efficiency ---
Model GKG2 40-4G-0065H-X-60
Family GK
Speed Fixed speed
Max Flow Rate 14,40 m³/h
H max 54,20 m
Pump casing Cast iron GJL 250 EN 1561
Min Flow Rate 0,70 m³/h
Min head 41,00 m
kW 6,50 kW
Power consumption ---
Efficiency ---
Model GKV2 65-40G-0031F-X-60
Family GK
Speed Fixed speed
Max Flow Rate 25,20 m³/h
H max 25,00 m
Pump casing Cast iron GJL 250 EN 1561
Min Flow Rate 1,80 m³/h
Min head 18,60 m
kW 3,10 kW
Power consumption ---
Efficiency ---
Model GKV2 65-40L-0031F-X-60
Family GK
Speed Fixed speed
Max Flow Rate 39,60 m³/h
H max 22,30 m
Pump casing Cast iron GJL 250 EN 1561
Min Flow Rate 1,80 m³/h
Min head 11,60 m
kW 3,10 kW
Power consumption ---
Efficiency ---
Model GKV4 65-55I-0016F-X-60
Family GK
Speed Fixed speed
Max Flow Rate 54,00 m³/h
H max 8,10 m
Pump casing Cast iron GJL 250 EN 1561
Min Flow Rate 3,20 m³/h
Min head 1,70 m
kW 1,60 kW
Power consumption ---
Efficiency ---
Model GKV4 65-55H-0021F-X-60
Family GK
Speed Fixed speed
Max Flow Rate 54,00 m³/h
H max 9,20 m
Pump casing Cast iron GJL 250 EN 1561
Min Flow Rate 3,20 m³/h
Min head 3,50 m
kW 2,10 kW
Power consumption ---
Efficiency ---
Model GKV4 65-55G-0026F-X-60
Family GK
Speed Fixed speed
Max Flow Rate 54,00 m³/h
H max 11,20 m
Pump casing Cast iron GJL 250 EN 1561
Min Flow Rate 3,20 m³/h
Min head 6,20 m
kW 2,60 kW
Power consumption ---
Efficiency ---

Filters for

Select motor phases (2)

Select motor power (42)

Hz (2)

Select motor poles (4)

Select suction flange dimension (18)

Select delivery flange dimension (16)

Filters for

Select motor phases (2)

Select motor power (42)

Hz (2)

Select motor poles (4)

Select suction flange dimension (18)

Select delivery flange dimension (16)