Pump Selector
booster set
Curve
Pump and motor datasheet
-
n (rpm):
2900
-
N. of impellers:
1
-
H max (m):
11.00
-
H min (m):
6.00
-
Q min (mc/h):
6.00
-
Q max (mc/h):
13.20
-
Pn (kW):
0.45
-
Pn (HP):
0.60
-
Impeller diameter (mm):
103.00
-
2° Impeller diameter (mm):
0.00
-
Motor type:
IM
-
Motor phases:
3~
-
Un (V):
230/400
-
fn (Hz):
50
-
Motor poles:
2
-
In (A):
2.3 / 1.3
-
Insulation class:
F
-
Service:
S1
-
Min liquid temperature (°C):
-10.00 °C
-
Efficiency Index (EI):
IE2-71.7
-
Ia/In:
3.50
-
Weight (kg):
20.900
-
Protection:
IP 54
Construction materials
-
Pump Casing:
Cast iron GJL 200 EN 1561
-
Lantern bracket:
Cast iron GJL 200 EN 1561
-
Impeller:
Cast iron GJL 200 EN 1561
-
Shaft:
Chrome steel 1.4105 EN 10088 (AISI 430F)
-
Mechanical Seal:
Carbon-Ceramic-NBR
-
Counterflanges:
Steel S235JR 1.0038 EN 10025-2
Booster set data
-
Total N° of Pumps:
1 nr
-
N° of Variable Speed Pumps:
1 nr
-
Control Panel Voltage:
400V AC
-
Control Panel Input Phases:
3
-
riftrgdata:
70M0041000000
-
Motor Voltage:
400V AC
-
Motor Phases:
3
-
Type motor:
71
BOOSTER SET CONSTRUCTION MATERIAL
-
Pressure Transducer:
Cr-Ni-Mo steel 1.4401 EN 10088 (AISI 316)
Dimensions (mm)
- a 320.00 mm
- fM 363.50 mm
- h1 90.00 mm
- h2 160.00 mm
- h6 273.50 mm
- l1 93.00 mm
- l2 100.00 mm
- AD 266.00 mm
- AG 190.00 mm
- AL 105.00 mm
- x 70.00 mm
- dn1 50 mm.
- dn2 50 mm.
NR
In-line pumps
Construction
Close-coupled, single-impeller, centrifugal pumps; electricmotor with extended shaft directly connected to the pump.NR, NR4 series: Single head electropumps.
NRD, NRD4: Twin head pump with built-in automatic switching valve. The two head can operate singularly or in parallel.
Pump casing with suction and delivery connections with the same diameter and on the same axis (in-line).
Version with frequency converter (on request)
Application
For clean liquids without abrasives, which are non-aggressive for the pump materials ( solids content up to 0.2%).For heating, air-conditioning, cooling and circulation plants.
For civil and industrial applications.
When low noise operation is required (n ? 1450 rpm).
Operating conditions
Liquid temperature from -10 °C to +90 °C.Ambient temperature up to 40° C.
Total suction lift up to 7 m.
Maximum permissible working pressure up to 10 bar.
Continuous duty.
Pump Selector