PumpSelector - Calpeda PumpSelector - Calpeda
logo pump selector

Pump Selector

pump

Model N 32L-200C-60 G
Family N
Speed Fixed speed
Max Flow Rate 27,00 m³/h
H max 46,10 m
Pump casing Cast iron GJL 200 EN 1561
Min Flow Rate 9,60 m³/h
Min head 25,60 m
kW 4,00 kW
Power consumption ---
Efficiency ---

Loading...

Pump and motor datasheet

mc/h
m
 
0
Your selection
9062
N 32L-200C-60 G
5000309005000

 

Curve





Loading...

Pump and motor datasheet

  • n (rpm):

    3450

  • N. of impellers:

    1

  • H max (m):

    46.10

  • H min (m):

    25.60

  • Q min (mc/h):

    9.60

  • Q max (mc/h):

    27.00

  • Pn (kW):

    4.00

  • Pn (HP):

    5.50

  • Impeller diameter (mm):

    160.00

  • Motor type:

    IM

  • Motor phases:

    3~

  • Un (V):

    380/660

  • fn (Hz):

    60

  • Motor poles:

    2

  • Service:

    S1

  • Min liquid temperature (°C):

    -10.00 °C

Construction materials

  • Pump Casing:

    Cast iron GJL 200 EN 1561

  • Casing Cover:

    Cast iron GJL 200 EN 1561

  • Impeller::

    Brass P-Cu Zn 40 Pb 2 UNI 5705

  • Shaft:

    Chrome steel 1.4105 EN 10088 (AISI 430F)

  • Mechanical Seal:

    Carbon-Ceramic-NBR

  • Counterflanges:

    Steel S235JR 1.0038 EN 10025-2

Dimensions (mm)

  • a 80.00 mm
  • a1 90.00 mm
  • f 360.00 mm
  • fM 903.00 mm
  • g2 100.00 mm
  • h2 180.00 mm
  • h3 260.00 mm
  • m4 880.00 mm
  • m5 850.00 mm
  • n4 300.00 mm
  • n5 240.00 mm
  • HD 437.00 mm
  • w1 15.00 mm
  • dn1 50
  • dn2 32
  • s1 14
Dimensions (mm)

N

End-suction centrifugal pumps EN 733

Construction

Single-stage end-suction centrifugal pumps, with bearing bracket.
The electropumps N, B-N, N4, B-N4 series comply with the European Regulation no. 547/2012 in force starting from 01.01.2013.
Nominal duty points and main dimensions in accordance with EN 733.
Back Pull-Out construction, for simple and quick dismantling and reassembly.
N, N4: version with pump casing and lanter bracket in cast iron.
B-N, B-N4: version with pump casing and lanter bracket in bronze (the pumps are supplied fully painted).
Rated speed of rotation (50 Hz): N = 2900 rpm. ; N4 = 1450 rpm.

Shaft sealing
Standardized mechanical seal in accordance with ISO 3069.
Stuffing box seal (on request).

Application

For clean liquids without abrasives, which are non-aggressive for the pump materials ( solids content up to 0.2%).
For water supply.
For heating, air-conditioning, cooling and circulation plants.
?For civil and industrial applications and for agriculture.
For fire fighting applications.
For irrigation.

Operating conditions

Liquid temperature from -10 °C to +90 °C.
Ambient temperature up to 40° C.
Total suction lift up to 7 m.
Maximum permissible working pressure up to 16 bar (10 bar per N,N4 32-12,16,20; N,N4 40-25; N,N4 50-20,25, N4 65-31, N,N4 100-250,315,400, N4 125-250,400, N4 150-400 and bronze version).
?Maximum permissible rotation speed: see table on page 32ad317a-c172-400f-958b-5c649d0cf20d

PDF request

calpeda.errore form countries
Please check your email address is valid
Please check the entered value is valid
Please check the entered value is valid

Please check the entered value is valid
* Mandatory fields