Pump Selector
pump
Curve
Loading...
Pump and motor datasheet
-
n (rpm):
2900
-
N. of impellers:
1
-
H max (m):
47.40
-
H min (m):
42.10
-
Q min (mc/h):
6.60
-
Q max (mc/h):
120.00
-
Pn (kW):
22.00
-
Pn (HP):
30.00
-
Impeller diameter (mm):
207.00
-
Motor poles:
2
-
Service:
S1
-
Min liquid temperature (°C):
-10.00 °C
Construction materials
-
Pump Casing:
Cast Iron GJS 400-15 EN 1563
-
Casing Cover:
Cast iron GJL 200 EN 1561
-
Impeller::
Cr-Ni-Mo steel 1.4401 EN 10088 (AISI 316)
-
Shaft:
Cr-Ni-Mo steel 1.4401 EN 10088 (AISI 316)
-
Mechanical Seal:
Carbon-Ceramic-NBR
Files
Dimensions (mm)
- a 125.00 mm
- b 80.00 mm
- f 470.00 mm
- h1 200.00 mm
- h2 280.00 mm
- l 80.00 mm
- l1 191.00 mm
- l2 210.00 mm
- m1 160.00 mm
- m2 120.00 mm
- n1 400.00 mm
- n2 315.00 mm
- n5 110.00 mm
- t 35.00 mm
- u 10.00 mm
- w 340.00 mm
- x 140.00 mm
- d 32
- dn1 100
- dn2 80
- s1 18
- s2 14
NF (NL)
Pompe centrifughe ad aspirazione assiale normalizzate EN 773 conformi alle norme UNI EN 12845 e UNI EN 12259-12
(NL)
Construction
Pompe centrifughe monogirante ad aspirazione assiale conformi alle norme UNI EN 12845 e UNI EN 12259-12.
Corpo pompa con bocca di aspirazione assiale e bocca di mandata radiale in alto, con dimensioni principali e prestazioni secondo EN 733.
Costruzione “Back Pull-Out”, per un facile e veloce smontaggio e rimontaggio.
Bocche: Flange PN 10-16, EN 1092-2 (PN 10 per DN 200).
Tenuta sull’albero
- Tenuta meccanica del tipo normalizzato secondo ISO 3069.
- Tenuta a treccia (a richiesta).
Application
Per liquidi puliti senza parti abrasive, non aggressivi per i materiali della pompa (con parti solide fino a 0,2% max).
Per impianti antincendio. UNI EN 12845, UNI EN 12259-12
(NL)Operating conditions
Temperatura liquido: da -10 °C a +90 °C.
Temperatura ambiente fino a 40 °C.
Altezza di aspirazione manometrica fino a 7 m.
Pressione finale massima ammessa nel corpo pompa: 16 bar (10 bar per NF 40-250; NF 100-250).
(NL)
Pump Selector