n (rpm):
3450
-
N. of impellers:
6
-
H max (m):
91.00
-
H min (m):
43.00
-
Q min (mc/h):
2.50
-
Q max (mc/h):
9.00
-
Pn (kW):
2.20
-
Pn (HP):
3.00
-
Impeller diameter (mm):
97.00
-
Motor type:
IM
-
Motor phases:
3~
-
Un (V):
220/380
-
fn (Hz):
60
-
Motor poles:
2
-
In (A):
11.1 / 6.4
-
Insulation class:
F
-
Service:
S1
-
Min liquid temperature (°C):
-15.00 °C
-
Efficiency Index (EI):
IE3-86.5
-
Protection:
IP 54
Construction materials
-
External jacket:
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
-
Suction Casing:
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
-
Delivery Casing::
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
-
Stage Casing::
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
-
Impeller:
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
-
Impeller wear ring:
PPS
-
Lower cover:
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
-
Upper cover:
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
-
Intermediate spacer sleeve:
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
-
Shaft:
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
-
Mechanical Seal:
Hard Metal-Carbon-EPDM
-
O-ring:
NBR
Files
Dimensions (mm)
- a 160.00 mm
- fM 641.00 mm
- g1 20.00 mm
- h1 50.00 mm
- m1 165.00 mm
- m2 100.00 mm
- n1 205.00 mm
- n2 180.00 mm
- AD 128.00 mm
- dn1 32
- dn2 32
- s 13
MXV-B
Vertical multi-stage close coupled stainless steel pumps
Construction
Vertical multi-stage close coupled pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line).All parts that come into contact with the liquid, are in chrome-nickel stainless steel.
Corrosion-resistant bearing sleeves lubricated by the pumped liquid.
Version with frequency converter (on request)
Application
For water supply systems.For clean non-explosive liquids, without solid, filamentary or abrasive matter and non-aggressive for stainless steel (with adaptation of sealing materials on request).
A universal pump for civil and industrial use, for pressureboosting systems, high-pressure washing plants, irrigation, agricultural uses and sport installations.
Operating conditions
Temperature of liquid: from -15 °C to +90 °C.Ambient temperature up to 40° C.
Maximum permissible pressure in pump casing: 16 bar.
Continuous duty.