Pump Selector
pump
Curve
Loading...
Pump and motor datasheet
-
n (rpm):
3450
-
N. of impellers:
5
-
H max (m):
80.00
-
H min (m):
40.40
-
Q min (mc/h):
1.00
-
Q max (mc/h):
5.00
-
Pn (kW):
1.50
-
Pn (HP):
2.00
-
Impeller diameter (mm):
98.50
-
Motor type:
IM
-
Motor phases:
3~
-
Un (V):
220/380
-
fn (Hz):
60
-
Motor poles:
2
-
In (A):
7.4 / 4.3
-
Insulation class:
F
-
Service:
S1
-
Min liquid temperature (°C):
-15.00 °C
-
Efficiency Index (EI):
IE3-85.5
-
la/In:
6.20
-
Protection:
IP 54
Construction materials
-
Pump Casing:
Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)
-
Casing Cover:
Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)
-
Stage Casing::
Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)
-
Impeller::
Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)
-
Impeller wear ring:
PPS
-
Intermediate spacer sleeve:
Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)
-
Shaft:
Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)
-
Mechanical Seal:
Ceramic Alumina-Carbon-EPDM
Files
Dimensions (mm)
- a 143.00 mm
- b 28.50 mm
- fM 465.00 mm
- g1 10.00 mm
- h1 126.00 mm
- h2 60.00 mm
- m1 28.00 mm
- m3 8.00 mm
- n1 146.00 mm
- n2 112.00 mm
- HD 218.00 mm
- w 88.00 mm
- w1 149.00 mm
- dn1 G 1 1/4
- dn2 G 1
- l5 175
- s 9.5
MXH
Horizontal multi-stage close coupled stainless steel pumps
Construction
Horizontal multi-stage close coupled pumps in chrome-nickel stainless steel.Compact and robust construction, without protruding flange and with single-piece lantern bracket and base.
Single-piece barrel casing, with front suction port above pumps axis and radial delivery at top.
Filling and draining plugs on the middle of the pump, accessible from any side (like the terminal box).
MXHL: Horizontal multi-stage close coupled pumps in chromenickel-molybdenum stainless steel AISI 316L.
Version with frequency converter (on request)
Application
For water supply systems.For clean liquids, without abrasives, which are non-aggressive for stainless steel (with suitable seal materials, on request).
Universal pump, for domestic use, for civil and industrial applications, for garden use and irrigation.
Operating conditions
Temperatura liquido: da -15 °C a +110 °C.Ambient temperature up to 40° C.
Pressione finale massima ammessa nel corpo pompa: 8 bar, 10 bar per MXH 20, 32, 48.
Continuous duty.
Pump Selector