PumpSelector - Calpeda PumpSelector - Calpeda
logo pump selector

Pump Selector

pump

photoRow
Model T 76/A
Family T, TP
Code 7000005200000
Speed Fixed speed
Max Flow Rate 3,60 m³/h
H max 70,00 m
Pump casing Cast iron GJL 200 EN 1561
Min Flow Rate 0,48 m³/h
Min head 26,00 m
kW 1,10 kW
Power consumption ---
Efficiency ---

Loading...

Pump and motor datasheet

Brass P-Cu Zn 40 Pb 2 UNI 5705 76.00
mc/h
m
 
0
Your selection
19138
T 76/A
7000005200000

 

Curve





Loading...

Pump and motor datasheet

  • n (rpm):

    2900

  • N. of impellers:

    1

  • H max (m):

    70.00

  • H min (m):

    26.00

  • Q min (mc/h):

    0.48

  • Q max (mc/h):

    3.60

  • Pn (kW):

    1.10

  • Pn (HP):

    1.50

  • Impeller diameter (mm):

    76.00

  • Motor type:

    IM

  • Motor phases:

    3~

  • Un (V):

    230/400

  • fn (Hz):

    50

  • Motor poles:

    2

  • In (A):

    5.3 / 3.1

  • PF:

    0.79

  • Insulation class:

    F

  • Service:

    S1

  • Min liquid temperature (°C):

    -10.00 °C

  • Efficiency Index (EI):

    IE3-82.7

  • la/In:

    4.90

  • Weight (kg):

    16.520

  • Protection:

    IP 54

Construction materials

  • Pump Casing:

    Cast iron GJL 200 EN 1561

  • Casing Cover:

    Cast iron GJL 200 EN 1561

  • Lantern bracket:

    Cast iron GJL 200 EN 1561

  • Impeller:

    Brass P-Cu Zn 40 Pb 2 UNI 5705

  • Shaft:

    Cr-Ni steel 1.4305 EN 10088 (AISI 303)

  • Mechanical Seal:

    Carbon-Ceramic-NBR

Dimensions (mm)

  • a 80.00 mm
  • a1 26.00 mm
  • fM 338.00 mm
  • h1 136.00 mm
  • h2 56.00 mm
  • A 125.00 mm
  • AA 30.00 mm
  • AB 155.00 mm
  • B 100.00 mm
  • BB 117.00 mm
  • H 80.00 mm
  • HA 10.00 mm
  • HD 208.00 mm
  • w 105.00 mm
  • dn1 G 1 1/4
  • dn2 G 1 1/4
Dimensions (mm)

T, TP

Peripheral pumps

Construction

Peripheral close coupled electropumps
T, TP: version with pump casing and lantern bracket in cast iron.
BT, BTP: versione con corpo pompa e raccordo in bronzo.
The pumps are supplied fully painted.

Application

For clean liquids without abrasives, without suspended solids, non-explosive, non-aggressive for the pump materials.
- For increasing network pressure (follow local specifications).
- For the reduced dimensions, these pumps are very well suitable to be mounted in cooling and air-conditioning machines and equipments, circulation, boiler feed.

Operating conditions

Liquid temperature from -10 °C to +90 °C.
Ambient temperature up to 40° C.
Total suction lift up to 7 m.
Maximum permissible pressure in the pump casing: 12,5 bar, (serie TP 16 bar).
Continuous duty.

PDF request

calpeda.errore form countries
Please check your email address is valid
Please check the entered value is valid
Please check the entered value is valid

Please check the entered value is valid
* Mandatory fields