PumpSelector - Calpeda PumpSelector - Calpeda
logo pump selector

Pump Selector

pump

Model CA 60E-60
Family CA
Speed Fixed speed
Max Flow Rate 0,90 m³/h
H max 29,00 m
Pump casing Cast iron GJL 200 EN 1561
Min Flow Rate 0,12 m³/h
Min head 10,00 m
kW 0,25 kW
Power consumption
Efficiency ---

Loading...

Pump and motor datasheet

mc/h
m
 
0
Your selection
118
CA 60E-60
70820011016

 

Curve





Loading...

Pump and motor datasheet

  • n (rpm):

    3450

  • N. of impellers:

    1

  • H max (m):

    29.00

  • H min (m):

    10.00

  • Q min (mc/h):

    0.12

  • Q max (mc/h):

    0.90

  • Pn (kW):

    0.25

  • Pn (HP):

    0.34

  • Impeller diameter (mm):

    59.85

  • Motor type:

    IM

  • Motor phases:

    3~

  • Un (V):

    220/380

  • fn (Hz):

    60

  • Motor poles:

    2

  • In (A):

    2 / 1.2

  • PF:

    0.71

  • Insulation class:

    F

  • Service:

    S1

  • Min liquid temperature (°C):

    -10.00 °C

  • Efficiency Index (EI):

    IE2-68.0

  • la/In:

    4.00

  • Weight (kg):

    5.800

  • Protection:

    IP 54

Construction materials

  • Pump Casing:

    Cast iron GJL 200 EN 1561

  • Lantern bracket:

    Cast iron GJL 200 EN 1561

  • Impeller::

    Brass P-Cu Zn 40 Pb 2 UNI 5705

  • Shaft:

    Chrome steel 1.4105 EN 10088 (AISI 430F)

  • Mechanical Seal:

    Carbon-Ceramic-NBR

Dimensions (mm)

Dimenstinos are not available. Please contact our sales department.export@calpeda.it

CA

Self-priming liquid ring pumps

Construction

Close-coupled self-priming liquid ring pumps with star impeller and anti-lock wear ring.
CA: version with pump casing and lantern bracket in cast iron.
B-CA: version with pump casing and lantern bracket in bronze
(the pumps are supplied fully painted).

Application

For clean liquids without abrasives, without suspended solids, non-explosive, non-aggressive for the pump materials.
If the liquid to be pumped has entrained air or gas or the flow in the suction pipe is not stable.
For drawing water out of a well.
For increasing network pressure (follow local specifications).

Operating conditions

Liquid temperature from -10 °C to +90 °C.
Ambient temperature up to 40° C.
Negative suction pressure up to 9 m.
Maximum permissible pressure in the pump casing: 6 bar.
Continuous duty.