Pump Selector
pump
Model
NR 65/160A/A
Family
NR
Code
70MA124100000
Speed
Fixed speed
Max Flow Rate
72,00 m³/h
H max
39,30 m
Pump casing
Cast iron GJL 200 EN 1561
Min Flow Rate
21,00 m³/h
Min head
25,30 m
kW
7,50
kW
Power consumption
---
Efficiency
---
Curve
Loading...
Pump and motor datasheet
-
n (rpm):
2900
-
N. of impellers:
1
-
H max (m):
39.30
-
H min (m):
25.30
-
Q min (mc/h):
21.00
-
Q max (mc/h):
72.00
-
Pn (kW):
7.50
-
Pn (HP):
10.00
-
Impeller diameter (mm):
174.00
-
Motor type:
IM
-
Motor phases:
3~
-
Un (V):
400/690
-
fn (Hz):
50
-
Motor poles:
2
-
In (A):
14.3 / 8.3
-
Insulation class:
F
-
Service:
S1
-
Min liquid temperature (°C):
-10.00 °C
-
Efficiency Index (EI):
IE3-90.1
-
Ia/In:
9.10
-
Weight (kg):
73.500
-
Protection:
IP 54
Construction materials
-
Pump Casing:
Cast iron GJL 200 EN 1561
-
Lantern bracket:
Cast iron GJL 200 EN 1561
-
Impeller:
Cast iron GJL 200 EN 1561
-
Shaft:
Chrome steel 1.4105 EN 10088 (AISI 430F)
-
Mechanical Seal:
Carbon-Ceramic-NBR
-
Counterflanges:
Steel S235JR 1.0038 EN 10025-2
Files
Dimensions (mm)
- a 340.00 mm
- fM 583.50 mm
- h1 105.00 mm
- h2 170.00 mm
- h6 478.50 mm
- j1 60.00 mm
- j2 50.00 mm
- j3 110.00 mm
- l1 121.00 mm
- l2 142.00 mm
- AD 167.00 mm
- x 95.00 mm
- dn1 65
- dn2 65
- s1 M10
NR
In-line pumps
Construction
Close-coupled, single-impeller, centrifugal pumps; electricmotor with extended shaft directly connected to the pump.NR, NR4 series: Single head electropumps.
NRD, NRD4: Twin head pump with built-in automatic switching valve. The two head can operate singularly or in parallel.
Pump casing with suction and delivery connections with the same diameter and on the same axis (in-line).
Version with frequency converter (on request)
Application
For clean liquids without abrasives, which are non-aggressive for the pump materials ( solids content up to 0.2%).For heating, air-conditioning, cooling and circulation plants.
For civil and industrial applications.
When low noise operation is required (n ? 1450 rpm).
Operating conditions
Liquid temperature from -10 °C to +90 °C.Ambient temperature up to 40° C.
Total suction lift up to 7 m.
Maximum permissible working pressure up to 10 bar.
Continuous duty.
Pump Selector