PumpSelector - Calpeda PumpSelector - Calpeda
logo pump selector

Pump Selector

pump

photoRow
Model NR 80/250C
Family NR
Code 70MA208000000
Speed Fixed speed
Max Flow Rate 141,00 m³/h
H max 55,40 m
Pump casing Cast iron GJL 200 EN 1561
Min Flow Rate 48,00 m³/h
Min head 36,90 m
kW 22,00 kW
Power consumption ---
Efficiency ---

Loading...

Pump and motor datasheet

Cast iron GJL 200 EN 1561 212.00
mc/h
m
 
0
Your selection
19211
NR 80/250C
70MA208000000

 

Curve





Loading...

Pump and motor datasheet

  • n (rpm):

    2900

  • N. of impellers:

    1

  • H max (m):

    55.40

  • H min (m):

    36.90

  • Q min (mc/h):

    48.00

  • Q max (mc/h):

    141.00

  • Pn (kW):

    22.00

  • Pn (HP):

    30.00

  • Impeller diameter (mm):

    212.00

  • Motor type:

    IM

  • Motor phases:

    3~

  • Un (V):

    400/690

  • fn (Hz):

    50

  • Motor poles:

    2

  • In (A):

    41 / 23.7

  • Insulation class:

    F

  • Service:

    S1

  • Min liquid temperature (°C):

    -10.00 °C

  • Efficiency Index (EI):

    IE3-92.7

  • la/In:

    10.70

  • Protection:

    IP 54

Construction materials

  • Pump Casing:

    Cast iron GJL 200 EN 1561

  • Lantern bracket:

    Cast iron GJL 200 EN 1561

  • Impeller::

    Cast iron GJL 200 EN 1561

  • Shaft:

    Cr-Ni steel 1.4305 EN 10088 (AISI 303)

  • Mechanical Seal:

    Carbon-Ceramic-NBR

  • Counterflanges:

    Steel S235JR 1.0038 EN 10025-2

Dimensions (mm)

  • a 620.00 mm
  • fM 846.00 mm
  • h1 150.00 mm
  • h2 310.00 mm
  • h6 696.00 mm
  • j1 85.00 mm
  • j2 42.50 mm
  • j3 147.20 mm
  • l1 179.00 mm
  • l2 192.00 mm
  • AD 208.00 mm
  • x 120.00 mm
  • dn1 80
  • dn2 80
  • s1 M10
Dimensions (mm)

NR

In-line pumps

Construction

Close-coupled, single-impeller, centrifugal pumps; electricmotor with extended shaft directly connected to the pump.

NR, NR4 series: Single head electropumps.
NRD, NRD4: Twin head pump with built-in automatic switching valve. The two head can operate singularly or in parallel.
Pump casing with suction and delivery connections with the same diameter and on the same axis (in-line).
Version with frequency converter (on request)

Application

For clean liquids without abrasives, which are non-aggressive for the pump materials ( solids content up to 0.2%).
For heating, air-conditioning, cooling and circulation plants.
For civil and industrial applications.
When low noise operation is required (n ? 1450 rpm).

Operating conditions

Liquid temperature from -10 °C to +90 °C.
Ambient temperature up to 40° C.
Total suction lift up to 7 m.
Maximum permissible working pressure up to 10 bar.
Continuous duty.