Pump Selector
pump
Model
NRD4 50/160C-60
Family
NR
Code
70MD0620001
Speed
Fixed speed
Max Flow Rate
18,90 m³/h
H max
6,50 m
Pump casing
Cast iron GJL 200 EN 1561
Min Flow Rate
5,40 m³/h
Min head
2,80 m
kW
0,37
kW
Power consumption
---
Efficiency
---
Curve
Loading...
Pump and motor datasheet
-
n (rpm):
1750
-
N. of impellers:
1
-
H max (m):
6.50
-
H min (m):
2.80
-
Q min (mc/h):
5.40
-
Q max (mc/h):
18.90
-
Pn (kW):
0.37
-
Pn (HP):
0.50
-
Impeller diameter (mm):
121.00
-
Motor type:
IM
-
Motor phases:
3~
-
Un (V):
220/380
-
fn (Hz):
60
-
Motor poles:
4
-
In (A):
2 / 1.1
-
PF:
0.67
-
Insulation class:
F
-
Service:
S1
-
Min liquid temperature (°C):
-10.00 °C
-
Efficiency Index (EI):
IE2-72.0
-
Protection:
IP 54
Construction materials
-
Pump Casing:
Cast iron GJL 200 EN 1561
-
Lantern bracket:
Cast iron GJL 200 EN 1561
-
Impeller:
Cast iron GJL 200 EN 1561
-
Shaft:
Cr-Ni steel 1.4305 EN 10088 (AISI 303)
-
Mechanical Seal:
Carbon-Ceramic-NBR
-
Counterflanges:
Steel S235JR 1.0038 EN 10025-2
Files
Dimensions (mm)
- a 340.00 mm
- fM 433.50 mm
- h1 90.00 mm
- h6 343.50 mm
- j5 310.00 mm
- l1 291.50 mm
- l2 291.50 mm
- AD 130.00 mm
- dn1 50
- dn2 50
NR
In-line pumps
Construction
Close-coupled, single-impeller, centrifugal pumps; electricmotor with extended shaft directly connected to the pump.NR, NR4 series: Single head electropumps.
NRD, NRD4: Twin head pump with built-in automatic switching valve. The two head can operate singularly or in parallel.
Pump casing with suction and delivery connections with the same diameter and on the same axis (in-line).
Version with frequency converter (on request)
Application
For clean liquids without abrasives, which are non-aggressive for the pump materials ( solids content up to 0.2%).For heating, air-conditioning, cooling and circulation plants.
For civil and industrial applications.
When low noise operation is required (n ? 1450 rpm).
Operating conditions
Liquid temperature from -10 °C to +90 °C.Ambient temperature up to 40° C.
Total suction lift up to 7 m.
Maximum permissible working pressure up to 10 bar.
Continuous duty.
Pump Selector