Pump Selector
pump
Model
NRS 80/250A
Family
NR
Code
70WA204000003
Speed
Fixed speed
Max Flow Rate
141,00 m³/h
H max
83,90 m
Pump casing
Cast iron GJL 200 EN 1561
Min Flow Rate
48,00 m³/h
Min head
71,50 m
kW
37,00
kW
Power consumption
---
Efficiency
---
Curve
Loading...
Pump and motor datasheet
-
n (rpm):
2900
-
N. of impellers:
1
-
H max (m):
83.90
-
H min (m):
71.50
-
Q min (mc/h):
48.00
-
Q max (mc/h):
141.00
-
Pn (kW):
37.00
-
Pn (HP):
50.00
-
Impeller diameter (mm):
249.00
-
Motor type:
IM
-
Motor phases:
3~
-
Un (V):
400/690
-
fn (Hz):
50
-
Motor poles:
2
-
Service:
S1
-
Min liquid temperature (°C):
-10.00 °C
Construction materials
-
Pump Casing:
Cast iron GJL 200 EN 1561
-
Casing Cover:
Cast iron GJL 200 EN 1561
-
Lantern bracket:
Cast iron GJL 200 EN 1561
-
Impeller:
Cast iron GJL 200 EN 1561
-
Shaft:
Cr-Ni-Mo steel 1.4401 EN 10088 (AISI 316)
-
Mechanical Seal:
Carbon-Ceramic-NBR
-
Counterflanges:
Steel S235JR 1.0038 EN 10025-2
Files
-
SECTIONS
-
IMAGES
-
INSTRUCTIONS
Dimensions (mm)
- a 620.00 mm
- fM 1138.00 mm
- h1 150.00 mm
- h2 310.00 mm
- h6 988.00 mm
- j1 85.00 mm
- j2 42.50 mm
- j3 147.20 mm
- l1 179.00 mm
- l2 192.00 mm
- AD 300.00 mm
- x 120.00 mm
- dn1 80
- dn2 80
- s1 M10
- P 400
NR
In-line pumps
Construction
Close-coupled, single-impeller, centrifugal pumps; electricmotor with extended shaft directly connected to the pump.NR, NR4 series: Single head electropumps.
NRD, NRD4: Twin head pump with built-in automatic switching valve. The two head can operate singularly or in parallel.
Pump casing with suction and delivery connections with the same diameter and on the same axis (in-line).
Version with frequency converter (on request)
Application
For clean liquids without abrasives, which are non-aggressive for the pump materials ( solids content up to 0.2%).For heating, air-conditioning, cooling and circulation plants.
For civil and industrial applications.
When low noise operation is required (n ? 1450 rpm).
Operating conditions
Liquid temperature from -10 °C to +90 °C.Ambient temperature up to 40° C.
Total suction lift up to 7 m.
Maximum permissible working pressure up to 10 bar.
Continuous duty.
Pump Selector