PumpSelector - Calpeda PumpSelector - Calpeda
logo pump selector

Pump Selector

pump

photoRow
Model MPSUM 507/A
Family MPSU
Code 76L14071000
Speed Fixed speed
Max Flow Rate 8,00 m³/h
H max 69,50 m
Pump casing
Min Flow Rate 2,50 m³/h
Min head 22,00 m
kW 1,50 kW
Power consumption ---
Efficiency ---

Loading...

Pump and motor datasheet

Noryl PPO-GF20 0.00
mc/h
m
 
0
Your selection
19113
MPSUM 507/A
76L14071000

 

Curve





Loading...

Pump and motor datasheet

  • n (rpm):

    2900

  • N. of impellers:

    7

  • H max (m):

    69.50

  • H min (m):

    22.00

  • Q min (mc/h):

    2.50

  • Q max (mc/h):

    8.00

  • Pn (kW):

    1.50

  • Pn (HP):

    2.00

  • Motor type:

    IM

  • Motor phases:

    1~

  • Un (V):

    230

  • fn (Hz):

    50

  • Motor poles:

    2

  • In (A):

    12

  • PF:

    0.80

  • C (mF):

    35

  • Vc (V):

    450

  • Insulation class:

    F

  • Service:

    S1

  • Max liquid temperature (°C):

    35

  • P1 (kW):

    2.20 kW

  • Protection:

    IP X8

Construction materials

  • External jacket:

    Cr-Ni steel 1.4301 EN 10088 (AISI 304)

  • Delivery Casing::

    Cr-Ni steel 1.4301 EN 10088 (AISI 304)

  • Stage Casing::

    Noryl PPO-GF20

  • Impeller:

    Noryl PPO-GF20

  • Oil chamber cover:

    Acciaio inox AISI 304

  • Motor jacket:

    Cr-Ni steel 1.4301 EN 10088 (AISI 304)

  • Shaft:

    Cr-Ni steel 1.4301 EN 10088 (AISI 304)

  • Upper Mechanical Seal:

    Ceramic Alumina-Carbon-NBR

  • Lower Mechanical Seal:

    Silicon Carbide-Silicon Carbide-NBR

  • Seal lubrication oil :

    Oil for food-Pharmaceutical machinery

Dimensions (mm)

  • a 100.00 mm
  • fM 720.00 mm
  • g1 2.00 mm
  • h1 50.00 mm
  • m1 180.00 mm
  • m2 100.00 mm
  • n1 205.00 mm
  • n2 180.00 mm
  • dn1 G 1 1/4
  • dn2 G 1 1/4
  • s1 11.5
Dimensions (mm)

MPSU

Vertical multi-stage close coupled pumps

Construction

5” Vertical multi-stage close coupled submersible or surface pumps.
External jacket in stainless steel AISI 304 and stages Noryl.
MPSUM with built-in capacitor, accessible through the delivery casing.
Suction connection on the lower casing and delivery connection on the top casing.
Motor cooled by the pumped water passing between the motor jacket and the external jacket.
Double mechanical shaft seal with interposed oil chamber.

Application

For clean water without abrasives or additives aggressive for the materials of the pump
For domestic, civil and industrial applications
For installation in confined space with minimum ventilation
For installation in locations subject to risk of temporary flooding, the pump can be fully immersed
For installation in areas exposed to water jetting
When low-noise operation is required

Operating conditions

Water temperature up to 35 °C.
Maximum permissible pressure in the pump casing: 8 bar.
Continuous duty.

PDF request

calpeda.errore form countries
Please check your email address is valid
Please check the entered value is valid
Please check the entered value is valid

Please check the entered value is valid
* Mandatory fields