Pump and motor datasheet
-
n (rpm):
3450
-
N. of impellers:
3
-
H max (m):
43.50
-
H min (m):
17.00
-
Q min (mc/h):
2.50
-
Q max (mc/h):
9.00
-
Pn (kW):
0.90
-
Pn (HP):
1.20
-
Motor type:
IM
-
Motor phases:
1~
-
Un (V):
220
-
fn (Hz):
60
-
Motor poles:
2
-
In (A):
7.2
-
PF:
0.97
-
C (mF):
20
-
Vc (V):
450
-
Insulation class:
F
-
Service:
S1
-
Max liquid temperature (°C):
35
-
Protection:
IP X8
Construction materials
-
External jacket:
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
-
Delivery Casing::
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
-
Stage Casing::
Noryl PPO-GF20
-
Impeller:
Noryl PPO-GF20
-
Oil chamber cover:
Acciaio inox AISI 304
-
Motor jacket:
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
-
Shaft:
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
-
Upper Mechanical Seal:
Ceramic Alumina-Carbon-NBR
-
Lower Mechanical Seal:
Silicon Carbide-Silicon Carbide-NBR
-
Seal lubrication oil :
Oil for food-Pharmaceutical machinery
Files
Dimensions (mm)
- a 100.00 mm
- fM 553.00 mm
- g1 2.00 mm
- h1 50.00 mm
- m1 180.00 mm
- m2 100.00 mm
- n1 205.00 mm
- n2 180.00 mm
- dn1 G 1 1/4
- dn2 G 1 1/4
- s1 11.5
MPSU
Vertical multi-stage close coupled pumps
Construction
5 Vertical multi-stage close coupled submersible or surface pumps.External jacket in stainless steel AISI 304 and stages Noryl.
MPSUM with built-in capacitor, accessible through the delivery casing.
Suction connection on the lower casing and delivery connection on the top casing.
Motor cooled by the pumped water passing between the motor jacket and the external jacket.
Double mechanical shaft seal with interposed oil chamber.
Application
For clean water without abrasives or additives aggressive for the materials of the pumpFor domestic, civil and industrial applications
For installation in confined space with minimum ventilation
For installation in locations subject to risk of temporary flooding, the pump can be fully immersed
For installation in areas exposed to water jetting
When low-noise operation is required
Operating conditions
Water temperature up to 35 °C.Maximum permissible pressure in the pump casing: 8 bar.