Pump Selector
pump
Curve
Loading...
Pump and motor datasheet
-
n (rpm):
2800
-
N. of impellers:
4
-
H max (m):
39.50
-
H min (m):
14.40
-
Q min (mc/h):
2.25
-
Q max (mc/h):
6.50
-
Pn (kW):
0.75
-
Pn (HP):
1.00
-
Impeller diameter (mm):
105.00
-
Motor type:
IM
-
Motor phases:
1~
-
Un (V):
230
-
fn (Hz):
50
-
Motor poles:
2
-
In (A):
4.8
-
PF:
0.96
-
C (mF):
30
-
Vc (V):
450
-
Insulation class:
F
-
Service:
S1
-
Min liquid temperature (°C):
-10.00 °C
-
Max liquid temperature (°C):
50
-
Efficiency Index (EI):
IE2-77.4
-
P1 (kW):
1.01 kW
-
Weight (kg):
11.500
-
Protection:
IP X4
Construction materials
-
Pump Casing:
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
-
Casing Cover:
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
-
Stage Casing::
Noryl PPO-GF20
-
Impeller:
Noryl PPO-GF20
-
Shaft:
Chrome steel 1.4105 EN 10088 (AISI 430F)
-
Mechanical Seal:
Carbon-Ceramic-NBR
Files
Dimensions (mm)
- a 145.00 mm
- b 30.00 mm
- fM 420.00 mm
- g1 10.00 mm
- h1 116.00 mm
- h2 119.00 mm
- m1 33.00 mm
- m2 25.00 mm
- m3 8.00 mm
- n1 146.00 mm
- n2 112.50 mm
- HD 228.00 mm
- w1 109.00 mm
- dn1 G 1
- dn2 G 1
- l5 161
E-MXP
Pressurized system with integrated control
Construction
Easy to install, compact and plug and play pressurized system with multistage pumps and integrated pressure transducer for automatic control of starting/stopping of the pump when utilizationpoints are opened/closed with a integrated non-return valve into the pump suction.
Application
For water supply.For domestic use, for garden use and irrigation.
Operating conditions
Liquid temperature: 0 °C to +50 °C.Ambient temperature up to +40 °C.
Maximum permissible pressure in the pump casing: 8 bar.
Continuous duty.
Pump Selector